Tender Details

5 each x fluke 1507 insulation tester

Tender Number:

GD12300867

Client:

City of Cape Town

Region:

Western Cape

Industry:

Other

Title:

5 each x fluke 1507 insulation tester

Closing Date:

23/02/2023 12:00

Site Inspection Date:

Tender Description:

RFQ Type Goods Goods Tools & Machinery Reference Number GD12300867 Title Fluke 1507 insulation tester Description 5 each x fluke 1507 insulation tester Specification* Fluke 1507 insulation tester Wherever reference is made to any particular Trade Mark, Name, Patent, Design, Type, Specific Origin or Producer, such reference shall be deemed to be accompanied by the words "or equivalent". 1. Rugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians 2. Automatically calculates Polarization Index and Dielectric Absorption Ratio 3. Makes repetitive tests simple and easy with a Compare (Pass/Fail) function 4. Offers multiple insulation test voltages 50 V, 100 V, 250 V, 500 V, and 1000 V Specifications AC/DC Voltage Measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz to 400 Hz ± (% of Rdg + Digits) ±(2% + 3) Input impedance 3 MO (nominal), <(><<)> 100 pF Common mode rejection ratio (1 kO unbalanced) > 60 dB at DC, 50 or 60 Hz Overload protection 600 V rms or DC Earth Bond Resistance Measurement Range/Resolution 20.00 O 0.01 O 200.0 O 0.1 O 2000 O 1.0 O 20.00 kO 0.01 kO Accuracy ±(1.5% + 3) Overload protection 2 V rms or DC Open circuit test voltage > 4.0 V, <(><<)> 8 V Short circuit current > 200.0 mA Insulation Specifications Measurement range 0.01 MO to 10 GO Test voltage 50 V, 100 V, 250 V, 500 V, 1000 V Test voltage accuracy + 20%, - 0% Short circuit current 1 mA nominal Auto discharge Discharge time <(><<)> 0.5 second for C = 1 µF or less Live circuit indicator Inhibit test if terminal voltage > 30 V prior to initialization of test Maximum capacitive load Operable with up to 1 µF load Measure accuracy 50 V ±(3% + 5) 100 V ±(3% + 5) 250 V ±(1.5% + 5) 500 V ±(1.5% + 5) 1000 V ±(1.5% + 5) to 2000 MO, ±(10% + 3) above 2000 MO General Specifications Maximum voltage applied to any terminal 600 V AC rms or DC Storage temperature -40°C to 60°C (-40°F to 140°F) Operating temperature -20°C to 55°C (-4°F to 131°F) Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <(><<)> 18°C or > 28°C (<(><<)> 64°F or > 82°F) Relative humidity 0% to 95% @ 10°C to 30°C (50°F to 86°F) 0% to 75% @ 30°C to 40°C (86°F to 104°F) 0% to 40% @ 40°C to 55°C (104°F to 131°F) Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) Electromagnetic compatibility In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1 1997) Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) Certifications CSA per standard CSA/CAN C22.2 No. 61010.1-04 TUV per standard IEC/EN 61010-1 2nd Edition Batteries Four AA batteries (NEDA 15A or IEC LR6) Battery life Insulation test use Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MO with a duty cycle of 5 seconds on and 25 seconds off. Resistance measurements Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room t emperature. These are standard tests of 1 O with a duty cycle of 5 seconds on and 25 seconds off. Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) Weight 550 g (1.2 lb) IP rating IP40 Altitude Operating 2000 m CAT IV 600 V, 3000 m CAT III 600 V Non-operating (storage) 12,000 m Over-range capability 110% of range Included accessories TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe CCT Representative Kylan Dreyer Kylan.dreyer@capetown.gov.za 021 444 3000 / 071 430 1143 Delivery Address Technician Blomtuin Depot # Water and Sanitation Department Water and Waste Directorate<(>&<)> Floor 1, B Allocation of Preference Points In order to qualify for preference points, it is the responsibility of the bidder to Submit a duly completed MBD 6.1 form (bidders must indicate how they claim points for each specific goal) Submit documentary proof of updated BBBEE certificate/sworn affidavit and/or CIPC certificate with each RFQ submission to validate specific goals. (if a bidder is registered and active on the City#s Supplier Database and has submitted the BBBEE certificate/ Sworn affidavit/ CIPC certificate, the submission of said documents is not necessary). It is therefore incumbent on suppliers to ensure that documents are kept updated. Failure to comply with the above will result in a zero (0) allocation for preference points. Delivery Date2023/06/30 Delivery ToWater Services - E&AM MAINTENANCE PLANT Delivery Address0000 TRADING SERVICES, Ottery Contact PersonKylan Dreyer Telephone Number0214443000 Cell Number Closing Date2023/02/23 Closing Time12 00 PM RFQ Submission Fax0214003977 RFQ Submission Fax 2 Buyer Email AddressGD1.Quotations@capetown.gov.za Buyer DetailsN.Mtati Buyer Phone0214009321 Attachments No Attachments NOTE This commodity has gone live for only quoting on the e-Procurement Portal. No manual submissions will be accepted for this commodities. Suppliers will need must log in to e-Services portal to access RFQs. Bids must be compliant with the Preferential Procurement Regulations, 2017 including but not limited to local content, functionality, price and preference, eligibility criteria and relevant statutory criteria. The details of this are contained in the RFQ document and/or the specification advertised via E-Procurement. Only locally produced goods or locally manufactured goods, meeting the stipulated minimum threshold for local production and content, will be considered, where applicable.